// Finding styles element var element = document.getElementById("iksm-dynamic-style"); if (!element) { // If no element (Cache plugins can remove tag), then creating a new one element = document.createElement('style'); var head = document.getElementsByTagName("head") if (head && head[0]) { head[0].appendChild(element); } else { console.warn("Iks Menu | Error while printing styles. Please contact technical support."); } } // Copying styles to tag element.innerHTML += ".iksm-7103 .iksm-terms{transition:all 400ms;animation:iks-fade-in 1000ms;}.iksm-7103 .iksm-terms-tree--level-1 > * > .iksm-term:not(:last-child){margin-bottom:0;}.iksm-7103 .iksm-term__inner{background-color:rgba(255,255,255,1);min-height:44px;transition:all 400ms;}.iksm-7103 .iksm-term__inner:hover{background-color:rgba(236,236,236,1);}.iksm-7103 .iksm-term--current > .iksm-term__inner{background-color:rgba(212,212,212,1);}.iksm-7103 .iksm-term__link{color:rgba(0,0,0,1);font-size:15px;line-height:15px;font-weight:400;text-decoration:none;padding-top:5px;padding-right:15px;padding-bottom:5px;padding-left:15px;transition:all 400ms;}.iksm-7103 .iksm-term__inner:hover .iksm-term__link{color:rgba(50,50,50,1);}.iksm-7103 .iksm-term__toggle__inner{transition:transform 400ms}.iksm-7103 .iksm-term--expanded > .iksm-term__inner > .iksm-term__toggle > .iksm-term__toggle__inner{transform:rotate(180deg);}.iksm-7103 .iksm-term__toggle{color:rgba(23,120,189,1);font-size:22px;align-self:stretch;height:unset;;width:40px;transition:all 400ms;}.iksm-7103 .iksm-term__toggle:hover{color:rgba(220,26,26,1);}.iksm-7103 .iksm-term__image-container{width:30px;min-width:30px;height:30px;min-height:30px;margin-right:15px;transition:all 400ms;}.iksm-7103 .iksm-term__image{background-size:contain;background-position:center;background-repeat:no-repeat;}.iksm-7103 .iksm-term__image-container:hover{background-size:contain;background-position:center;background-repeat:no-repeat;}.iksm-7103 .iksm-term__inner:hover .iksm-term__image-container{background-size:contain;background-position:center;background-repeat:no-repeat;}.iksm-7103 .iksm-term__inner:focus .iksm-term__image-container{background-size:contain;background-position:center;background-repeat:no-repeat;}.iksm-7103 .iksm-term--current > .iksm-term__inner .iksm-term__image-container{background-size:contain;background-position:center;background-repeat:no-repeat;}.iksm-7103 .iksm-term--child .iksm-term__inner .iksm-term__image-container{background-size:contain;background-position:center;background-repeat:no-repeat;}.iksm-7103 .iksm-term--child .iksm-term__inner .iksm-term__image-container:hover{background-size:contain;background-position:center;background-repeat:no-repeat;}.iksm-7103 .iksm-term--child .iksm-term__inner .iksm-term__image-container:focus{background-size:contain;background-position:center;background-repeat:no-repeat;}.iksm-7103 .iksm-term--child.iksm-term--current > .iksm-term__inner .iksm-term__image-container{background-size:contain;background-position:center;background-repeat:no-repeat;}.iksm-7103 .iksm-term__text{flex: unset}.iksm-7103 .iksm-term__posts-count{color:rgba(133,133,133,1);font-size:16px;margin-left:12px;font-weight:400;transition:all 400ms;}"; // Removing this script var this_script = document.getElementById("styles-copier-6afa095acd115"); if (this_script) { // Cache plugins can remove tag this_script.outerHTML = ""; if (this_script.parentNode) { this_script.parentNode.removeChild(this_script); } }

Auto ELISA Processor SX25-AEP8001

Model No: SX25-AEP8001 

Features:

  • 8 sampling channels, 16 incubation boards, and 3 washers.

  • Utilizes pressure-type liquid detection.

  • Includes TIP and clot detection functions.

  • High-precision pipetting with a minimum volume of 5μl.

  • Position sensing for real-time monitoring of gripper status.

  • Adjustable multi-spacing and multi-strength grippers, suitable for handling microplates and plate covers of varying sizes.

  • Dual thread control, enabling simultaneous operation of the sampling arm without interference.

Technical Parameters:

Sample & Reagent Unit:

  • Sample Racks: 12*20 push-pull sample rack with detection
  • Sampling Channel: 8 channels
  • Liquid Level Detection: Air pressure level detection, needle blocking intelligent detection
  • TIP: 5 TIP racks
  • Pipetting: 5~1000μl, capable of parallel sampling
  • Pipetting Precision:
    • 100μl: CV ≤ 1.0%, accuracy ≤ 2.5%
    • 1000μl: CV ≤ 0.5%, accuracy ≤ 1.0%
  • Reagent Position:
    • 6 reagent positions
    • 40 quality control positions
    • 12 reagent bottles
    • 25 reagent tanks (reagent tank with code identification)

Washing Unit:

  • Washer: 3 units with on-board detection function
  • Washing Head: 16-channel (32-pin), double-row cleaning, hanging installation, with leakage recovery
  • Injection Uniformity: CV < 1.5%
  • Washing Residual: < 1μl (residual volume per well)

Reading Unit:

  • Reading Channel: 8 independent photometric channels
  • Linear Range: 0.000~3.000 Abs
  • Repeatability: CV ≤ 1.0%
  • Stability: ≤ ±0.003 Abs
  • Optical Filters: 4 standard filters (405, 450, 492, 630nm), total of 10 filter positions
  • Reading Accuracy:
    • ≤ ±0.02 Abs from 0.0 to 1.0 OD
    • ≤ ±0.03 Abs from 1.0 to 2.0 OD
  • Sensitivity: ≥ 0.01 mg/L
  • Channel Difference: ≤ 0.02 Abs

Incubation Unit:

  • Incubators: 16 shaking incubators
  • Cover Positions: 4 (16 covers)
  • Heating Method: Dry heating with cover
  • Shaking Function: Horizontal circular oscillation, 1~3 levels adjustable, amplitude 2.5mm
  • Temperature Range: RT ~ 60°C
  • Temperature Uniformity: ±0.5°C
  • Temperature Fluctuation: ±0.5°C

Data Management:

  • Software: Compatible with Windows 7 or higher
  • LIS System: Bi-directional, supports HL7 protocol
  • Results: Absorbance and results reviewable by software
  • Printer: External optional
  • Built-in Scanner: Optional

Other Functions:

  • Biosafety Protection: Optional (Negative pressure working zone, HEPA filter)
  • Disinfection: UV lamp
  • Lighting: LED
  • IAP Function: Firmware can be upgraded online at any time

Working Conditions:

  • Power Supply: AC 100~240V, 50/60Hz
  • Temperature: 10~40°C
  • Humidity: 30~80%

Size & Weight:

  • External Size (W * D * H): 1925 * 824 * 1660 mm
  • Package Size (W * D * H) mm:
    • Machine: 2095 * 950 * 1160 mm
    • Base Stand: 2095 * 950 * 1005 mm
    • Accessories: 1560 * 930 * 530 mm
  • Net Weight (kg):
    • Machine: 320
    • Base Stand: 153
    • Accessories: 68
  • Gross Weight (kg):
    • Machine: 420
    • Base Stand: 245
    • Accessories: 122

Reviews

There are no reviews yet.

Be the first to review “Auto ELISA Processor SX25-AEP8001”

Your email address will not be published. Required fields are marked *


document.addEventListener("DOMContentLoaded", function() { document.body.addEventListener("click", function(event) { if (event.target.matches(".comment-reply-link, #cancel-comment-reply-link")) { turnstile.reset(".comment-form .cf-turnstile"); } }); });
No products were found of your matching selection