// Finding styles element var element = document.getElementById("iksm-dynamic-style"); if (!element) { // If no element (Cache plugins can remove tag), then creating a new one element = document.createElement('style'); var head = document.getElementsByTagName("head") if (head && head[0]) { head[0].appendChild(element); } else { console.warn("Iks Menu | Error while printing styles. Please contact technical support."); } } // Copying styles to tag element.innerHTML += ".iksm-7103 .iksm-terms{transition:all 400ms;animation:iks-fade-in 1000ms;}.iksm-7103 .iksm-terms-tree--level-1 > * > .iksm-term:not(:last-child){margin-bottom:0;}.iksm-7103 .iksm-term__inner{background-color:rgba(255,255,255,1);min-height:44px;transition:all 400ms;}.iksm-7103 .iksm-term__inner:hover{background-color:rgba(236,236,236,1);}.iksm-7103 .iksm-term--current > .iksm-term__inner{background-color:rgba(212,212,212,1);}.iksm-7103 .iksm-term__link{color:rgba(0,0,0,1);font-size:15px;line-height:15px;font-weight:400;text-decoration:none;padding-top:5px;padding-right:15px;padding-bottom:5px;padding-left:15px;transition:all 400ms;}.iksm-7103 .iksm-term__inner:hover .iksm-term__link{color:rgba(50,50,50,1);}.iksm-7103 .iksm-term__toggle__inner{transition:transform 400ms}.iksm-7103 .iksm-term--expanded > .iksm-term__inner > .iksm-term__toggle > .iksm-term__toggle__inner{transform:rotate(180deg);}.iksm-7103 .iksm-term__toggle{color:rgba(23,120,189,1);font-size:22px;align-self:stretch;height:unset;;width:40px;transition:all 400ms;}.iksm-7103 .iksm-term__toggle:hover{color:rgba(220,26,26,1);}.iksm-7103 .iksm-term__image-container{width:30px;min-width:30px;height:30px;min-height:30px;margin-right:15px;transition:all 400ms;}.iksm-7103 .iksm-term__image{background-size:contain;background-position:center;background-repeat:no-repeat;}.iksm-7103 .iksm-term__image-container:hover{background-size:contain;background-position:center;background-repeat:no-repeat;}.iksm-7103 .iksm-term__inner:hover .iksm-term__image-container{background-size:contain;background-position:center;background-repeat:no-repeat;}.iksm-7103 .iksm-term__inner:focus .iksm-term__image-container{background-size:contain;background-position:center;background-repeat:no-repeat;}.iksm-7103 .iksm-term--current > .iksm-term__inner .iksm-term__image-container{background-size:contain;background-position:center;background-repeat:no-repeat;}.iksm-7103 .iksm-term--child .iksm-term__inner .iksm-term__image-container{background-size:contain;background-position:center;background-repeat:no-repeat;}.iksm-7103 .iksm-term--child .iksm-term__inner .iksm-term__image-container:hover{background-size:contain;background-position:center;background-repeat:no-repeat;}.iksm-7103 .iksm-term--child .iksm-term__inner .iksm-term__image-container:focus{background-size:contain;background-position:center;background-repeat:no-repeat;}.iksm-7103 .iksm-term--child.iksm-term--current > .iksm-term__inner .iksm-term__image-container{background-size:contain;background-position:center;background-repeat:no-repeat;}.iksm-7103 .iksm-term__text{flex: unset}.iksm-7103 .iksm-term__posts-count{color:rgba(133,133,133,1);font-size:16px;margin-left:12px;font-weight:400;transition:all 400ms;}"; // Removing this script var this_script = document.getElementById("styles-copier-6b0b91bb79844"); if (this_script) { // Cache plugins can remove tag this_script.outerHTML = ""; if (this_script.parentNode) { this_script.parentNode.removeChild(this_script); } }

Gas Chromatograph SX25-GC900

Model No: SX25-GC900

Features:

  • Ethernet Communication Interface:
    Enables long-distance data transmission through an enterprise's internal LAN, making analysis data management more efficient and centralized.

  • Innovative Injection Port Design:
    Eliminates injection discrimination. The dual-column compensation function addresses baseline drift during temperature programming and reduces background noise, effectively lowering the detection limit.

  • Optimized Vaporization Chamber:
    Designed with minimal dead volume. Accessories like injection pads, liners, polarizers, collectors, and nozzles can be replaced single-handedly. Major components like packed columns, capillary injectors, TCD, and FID detectors are easily serviced with just a wrench, ensuring quick and convenient maintenance.

  • Intelligent Rear Door System:
    Features stepless variable air volume control for faster system stabilization during programmed heating or cooling.

  • Versatile Inlet Configuration:
    Supports up to four types of inlets, including packed column and capillary column split/splitless systems. Compatible with a variety of sample introduction systems:

    • Automatic/manual gas injectors

    • Headspace samplers

    • Thermal desorption units

    • Pyrolysis furnaces

    • Methane reformers

  • User-Friendly Interface:
    Equipped with a 4.3-inch color LCD touch screen and keyboard input for intuitive user interaction.

  • Dual-Stable Gas Path Design:
    Incorporates primary pressure stabilizer valves and secondary stabilizer/pressure valves for stable and precise gas flow control.

  • High-Precision Temperature Control:
    Includes seven independent temperature control zones with ±0.1°C accuracy, ensuring consistent operation.

  • Safety Functions:

    • Dual over-temperature protection

    • Power-off protection

    • Fault self-check and alarm system

  • Linkage Trigger Signal System:
    Allows synchronized data acquisition with other connected devices.

Technical Parameters

Specification Details
Model SX25-GC900
Oven Temperature Range RT +5°C ~ 450°C
Temperature Accuracy ≤ ±0.1°C
Temperature Programming 20-phase
Max Heating Rate 40°C/min
Time Range 0–655 min
Oven Internal Size 250 × 270 × 170 mm

Detector Options

Hydrogen Flame Ionization Detector (FID)

  • Detection Limit: ≤ 5 × 10⁻¹² g/s
    (100 ng/µL n-hexadecane-isooctane solution)
  • Operating Temperature: 450°C
  • Compatible with packed and capillary columns
  • Baseline Drift: ≤ 2 × 10⁻¹³ A / 30 min
  • Baseline Noise: ≤ 3 × 10⁻¹⁴ A
  • Linear Range: ≥ 10⁷

Thermal Conductivity Detector (TCD)

  • Sensitivity: > 5000 mV·mL/mg
    (50 mg/mL toluene-benzene solution)
  • Operating Temperature: 400°C
  • Baseline Drift: ≤ 0.1 mV / 30 min
  • Baseline Noise: ≤ 0.03 mV
  • Linear Range: ≥ 10⁵ (±10%)

Flame Photometric Detector (FPD)

  • S Detection Limit: ≤ 5 × 10⁻¹² g/s
  • P Detection Limit: ≤ 4 × 10⁻¹² g/s
    (10 ng/µL methyl parathion-ethanol solution)
  • S Linear Range: ≥ 10³
  • P Linear Range: ≥ 10⁴
  • Operating Temperature: 350°C

Injection Methods Supported

  1. Packed column injection
  2. Packed column gasification injection
  3. Capillary split/splitless injection (with back pressure valve control and linear split)
  4. Six-way valve gas injection
  5. Online injection – 24-hour continuous unattended operation

Power Supply

AC 220V ±10%, 50/60Hz

Accessories

  • Standard Accessories:
    • FID Detector
    • Chromatography Workstation Software
    • Capillary Sampler
  • Optional Accessories:
    • TCD Detector
    • FPD Detector
    • Sample Injection System
    • Chromatographic Columns
    • Nickel Catalytic Converter

Dimensions & Weight

Specification Details
External Size 530 × 502 × 508 mm
Net Weight 42 kg
Package Size 750 × 710 × 720 mm
Gross Weight 60 kg

 

Reviews

There are no reviews yet.

Be the first to review “Gas Chromatograph SX25-GC900”

Your email address will not be published. Required fields are marked *


document.addEventListener("DOMContentLoaded", function() { document.body.addEventListener("click", function(event) { if (event.target.matches(".comment-reply-link, #cancel-comment-reply-link")) { turnstile.reset(".comment-form .cf-turnstile"); } }); });
No products were found of your matching selection